Water leaks at the sealing head gland nut (HP outlet)
Water at the gland nut where the HP tubing leaves the sealing head comes from the tubing connection.
The cone does not seal without the correct torque.
How to check: Torque the tubing gland nut (pressure released).
| Photo | Art. no. | Description | Excl. VAT | |
|---|---|---|---|---|
![]() | 10259 | Gland nut 1/4" , 10078459
NutKMT |
€ 8.16 | |
![]() | 10260 | Gland nut 3/8", 10078129
NutKMT |
€ 10.46 | |
![]() | 11225 | Gland nut, Swivel
NutKMT, Flow, Techni, Accustream |
€ 47.88 | |
![]() | 11373 | Gland nut, 1/4, UHP, 20452962
NutKMT |
€ 26.28 | |
![]() | 12066 | Gland Nut 1/4" , 701403 (Metric)
NutBFT, Allfi, Bystronic, STM |
€ 20.40 |
Too many or too few threads behind the collar stop the tube from seating.
How to check: About 1.5 to 2.5 threads should be visible past the collar.
Thread fatigue or a cracked tube end leaks even at torque.
How to check: Inspect threads and tube end; replace cracked parts.
Related problems
General advice based on manufacturer manuals and service practice. Always follow the manual of your machine. Not sure? .