///Water leaks at the sealing head gland nut (HP outlet)
Intensifier: high-pressure side

Water leaks at the sealing head gland nut (HP outlet)

Water at the gland nut where the HP tubing leaves the sealing head comes from the tubing connection.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 3 checked
01HP tube gland nut loose Most likely

The cone does not seal without the correct torque.

How to check: Torque the tubing gland nut (pressure released).

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10259 Gland nut 1/4" , 10078459
NutKMT
KMT 10078459 € 8.16
10260 Gland nut 3/8", 10078129
NutKMT
KMT 49864564 · KMT 10078129 € 10.46
11225 Gland nut, Swivel
NutKMT, Flow, Techni, Accustream
— € 47.88
11373 Gland nut, 1/4, UHP, 20452962
NutKMT
KMT 20452962 € 26.28
12066 Gland Nut 1/4" , 701403 (Metric)
NutBFT, Allfi, Bystronic, STM
Allfi 701403 · BFT VDS064705/256 € 20.40

02Wrong collar position Possible

Too many or too few threads behind the collar stop the tube from seating.

How to check: About 1.5 to 2.5 threads should be visible past the collar.

03Fatigue crack in gland nut or tube end Less likely

Thread fatigue or a cracked tube end leaks even at torque.

How to check: Inspect threads and tube end; replace cracked parts.