///HP swivel leaks or turns stiffly
HP tubing, fittings & swivels

HP swivel leaks or turns stiffly

Swivels let the HP line rotate. Worn seals or bearings leak and get stiff.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 2 checked
01Worn swivel seals Most likely

Water escapes at the swivel weep hole.

How to check: Rebuild with a swivel maintenance kit.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10629 Thrust Needle Bearing Swivel, 10084713
StemKMT
KMT 91960005 · KMT 10084713 € 4.80
10630 Thrust Washer Swivel, 10094647
Fitting & adapterKMT
KMT 91959684 · KMT 10094647 € 4.20
10631 Spindle Swivel, 1/4'' Female, 91960021
Fitting & adapterKMT
KMT 91959668 · KMT CJ318088 € 258.00
10632 Cap Assembly, Swivel, 91959643
AssemblyKMT
KMT 91959643 · KMT 00080125 € 93.60
10649 Body Swivel Joint 1/4 90°, 91959635
Valve bodyKMT
KMT 91959635 · KMT DJ301288 € 418.80

02Worn thrust bearing Possible

The swivel turns hard and loads the tubing.

How to check: Replace bearing and washers.

Related problems

General advice based on manufacturer manuals and service practice. Always follow the manual of your machine. Not sure? .