///Pressure is erratic or cannot reach the set value (proportional control)
Intensifier: hydraulics & oil

Pressure is erratic or cannot reach the set value (proportional control)

On pumps with proportional pressure control a blocked valve screen gives erratic pressure.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 2 checked
01Blocked screen in the proportional valve Most likely

Debris restricts the pilot flow.

How to check: Remove the valve and clean the screen.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10519 Directional Control Valve, 05053905
ValveKMT
KMT 05053905 · KMT 20437164 € 2,340.00
11014 Solenoid, 10185585
KMT
KMT 10185585 € 137.88
11454 Directional Spool Valve 24V, 05053905
ValveKMT
05053905 € 420.00
11456 Magnetic coil 24V 4-way valve
CoilKMT
— € 132.00
11596 R-ring kit for 4-way spool valve rexroth, 20453037
Repair kitKMT
20453037 € 22.20

02Dirty hydraulic oil Possible

Contaminated oil blocks small valve passages.

How to check: Change the oil filter and check oil condition.

Related problems