///The pump does not shift or stops at the end of a stroke
Intensifier: hydraulics & oil

The pump does not shift or stops at the end of a stroke

The intensifier changes direction when a sensor sees the piston at the end and the directional valve switches the oil.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Quick questionsYour answers put the most likely cause on top.
What do the proximity switch lights do?
2Check the causes, most likely first 0 of 4 checked
01Faulty proximity switch Most likely

No end-of-stroke signal, so no shift.

How to check: The switch LED should light at the stroke end. Both lights on at once also means a fault.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10095 Proximity Switch, 05127584
Gauge & sensorKMT
KMT 20453934 · KMT 05127584 € 379.00
10154 O-ring Spacer proximity switch, 05144191
O-ringKMT
KMT 05144191 · KMT 05144183 € 1.32
10169 Spacer proximity switch, 05144183
Bushing & ringKMT
KMT 05144183 € 25.92
10225 Screw, Proximity Switch M6x25MM, 10064707
Screw & boltKMT
10064707 € 1.08
10585 Proximity Switch 75/100s, 20453925
Gauge & sensorKMT
KMT 20453925 € 538.80

02Directional valve or coil Possible

A burned coil or sticking spool does not switch the oil.

How to check: Measure coil voltage; some valves can be shifted by hand.

03Stuck indicator pin Possible

The pin that triggers the switch must move freely.

How to check: Remove and check that the pin moves to the bottom of its bore.

04Cutting head off / intensifier disabled Less likely

With no flow the intensifier simply holds.

How to check: Check the on/off valve and the enable setting.