///Low inlet (cutting) water pressure
Inlet water, booster & filters

Low inlet (cutting) water pressure

The intensifier needs a steady water supply, often at least 3-4 bar after the filters.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 3 checked
01Clogged filter element Most likely

A dirty filter drops pressure.

How to check: Compare pressure before and after the filter.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10633 Filter element 0,5 Micron 10"
FilterKMT, BFT, Flow
Flow A-1449 € 13.08
10634 Filter element 10 Micron 20", 49834716
FilterKMT, Flow
KMT 49834716 € 19.08
10635 Filter element 10 Micron 10", 10106722
FilterKMT, Flow, CMS / Tecnocut
KMT 10106722 € 6.60
10661 Filter element 5 Micron 10"
FilterKMT, BFT, Flow, STM
BFT XF58/220 · STM HD400011 € 10.20
10714 Water Filter Housing. SS, 250 psi, 3/4" FNPT, 72118339
FilterKMT
KMT 72118339 € 286.80

02Weak booster pump Possible

The booster no longer makes enough pressure.

How to check: Deadheaded booster pressure should reach its rated value.

03Air in the water line Less likely

Trapped air reduces flow.

How to check: Bleed air from the plumbing.

Related problems