///Inlet water manifold or LP line gets hot
Intensifier: high-pressure side

Inlet water manifold or LP line gets hot

Hot water on the low-pressure side means high-pressure water leaks back through the inlet.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 2 checked
01Cracked or eroded inlet poppet Most likely

The inlet check valve leaks back; pressure can drop by up to half.

How to check: Inlet side very hot; replace the inlet poppet.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10084 Spring LP-Inlet SLIV/SLIV+, 49884562
SpringKMT
KMT 49884562 € 4.32
10085 Spring Check valve, 05147863
SpringKMT, H2O
KMT 05147863 · KMT 49894116 € 1.90
10088 Flat Outlet Poppet, 05116561
PoppetKMT, H2O
KMT 05116561 · KMT 05112776 € 31.80
10089 Retainer, Poppet, LP-IN SLIV, 10118552
PoppetKMT
KMT 10118552 · KMT 05144670 € 42.29
10090 Spring Guide, Poppet, 05116751
PoppetKMT, H2O
KMT 05116751 · H2O 102008-1 € 37.80

02Static seal leaking Possible

Same symptoms as a broken inlet poppet.

How to check: Inspect static seal and cylinder end.