///Boosted water temperature is high
Inlet water, booster & filters

Boosted water temperature is high

Warm inlet water shortens seal life and can trigger alarms.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 2 checked
01Orifice blocked Most likely

Water circulates without flowing out and heats up.

How to check: Check orifice for debris.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10226 Orifice 0,10 mm, 1010
OrificeKMT
KMT A2260004 € 11.26
10227 Orifice 0,12 mm, 1012
OrificeKMT
1012 € 11.26
10228 Orifice 0,15 mm, 1015
OrificeKMT
KMT A2260006 € 11.26
10229 Orifice 0,17 mm, 1017
OrificeKMT
KMT 49863590 · KMT A2260006 € 11.26
10230 Orifice 0,20 mm, 1020
OrificeKMT
KMT 49865850 € 11.26

02Pump dead-headed for a long time Possible

Holding pressure without cutting heats the water.

How to check: Reduce idle time at pressure.

Related problems