///Cylinder over-temperature warning or shutdown
Direct-drive plunger pumps

Cylinder over-temperature warning or shutdown

Heat at a cylinder means high-pressure water leaks inside that cylinder.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Quick questionsYour answers put the most likely cause on top.
Is the warning on one cylinder or all?
2Check the causes, most likely first 0 of 3 checked
01Dynamic seal failing Most likely

The plunger seal leaks and heats the cylinder.

How to check: Check pump hours and fit the maintenance kit.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10377 End Cap Wrench, 8007923
KMT
KMT 80079239 € 70.80
10511 Dynamic Seal Assembly, SLPRO, 90K, 20479499
AssemblyKMT
KMT 20479499 € 159.60
11104 Maintenance kit, KMT intensifier tools, 05072723
Repair kitKMT
05072723 € 898.80
12661 Dynamic seal kit - Hyplex Prime, 050626-1
Seal kitKMT, Flow
Flow 050626-1 € 95.00
11489 Swivel maintenance kit, 007117-1
Repair kitFlow
007117-1 € 274.80

02Debris under outlet or inlet poppet Possible

A held-open poppet lets water flow back.

How to check: Inspect check valve poppets and seats.

03Inlet water too warm Less likely

Warm inlet water (above about 18 °C) shortens seal life.

How to check: Measure inlet water temperature.

Related problems