///Suspected cracked HP cylinder
Intensifier: high-pressure side

Suspected cracked HP cylinder

A cracked cylinder leaks at the end, back through the inlet valve, or violently through the wall.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 2 checked
01Fatigue crack at the dynamic end Most likely

Water leaks between guide and cylinder.

How to check: Leak returns right after a seal change.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10107 HP Cylinder SLIV, 05059712
CylinderKMT
KMT 05059712 · KMT 20460891 € 1,250.00
10133 HP Cylinder SLV, 05144647
CylinderKMT
KMT 05144647 · KMT 20479503 € 1,450.00
10209 Liner - UHP Cylinder .88 plunger, 20474333
PlungerKMT
KMT 20474333 € 102.00
10210 Liner - HP Cylinder Liner .88, 20497767
CylinderKMT
KMT 10110419 · KMT 05132246 € 101.15
10211 Liner, 75S/100S SHIP, 72110945
KMT
KMT 72110945 · KMT 05144555 was discontinued € 106.80

02Crack at the static end Possible

Water leaks back through the inlet; cylinder and manifold get very hot.

How to check: Very hot cylinder and inlet manifold without visible leak.

Related problems