///Water sprays from the middle of the HP cylinder
Intensifier: high-pressure side

Water sprays from the middle of the HP cylinder

A violent leak through the cylinder wall is a fracture. Stop the pump at once.

Safety first: Switch off the pump, release all pressure (open the on/off valve or bleed-down valve) and lock out before you open any high-pressure part. Never put a hand or tool near a running jet.
1Check the causes, most likely first 0 of 1 checked
01Fractured HP cylinder Most likely

Fatigue cracks can run through the wall.

How to check: Stop, release pressure and replace the cylinder.

PhotoArt. no.DescriptionReplaces OEMExcl. VAT
10107 HP Cylinder SLIV, 05059712
CylinderKMT
KMT 05059712 · KMT 20460891 € 1,250.00
10133 HP Cylinder SLV, 05144647
CylinderKMT
KMT 05144647 · KMT 20479503 € 1,450.00
10209 Liner - UHP Cylinder .88 plunger, 20474333
PlungerKMT
KMT 20474333 € 102.00
10210 Liner - HP Cylinder Liner .88, 20497767
CylinderKMT
KMT 10110419 · KMT 05132246 € 101.15
10211 Liner, 75S/100S SHIP, 72110945
KMT
KMT 72110945 · KMT 05144555 was discontinued € 106.80

Related problems

General advice based on manufacturer manuals and service practice. Always follow the manual of your machine. Not sure? .